Rapid Response Residential Fire Sprinkler System Concealed Fire Sprinkler Heads

Product Details
Customization: Available
Sprinkler Installation: Upright
Sprinkler Head Type: Closed
Still deciding? Get samples of US$ 4/Piece
Order Sample
Shipping & Policy
Shipping Cost: Contact the supplier about freight and estimated delivery time.
Payment Methods:
visa mastercard discover JCB diners club american express T/T
PIX SPEI OXXO PSE OZOW
  Support payments in USD
Secure payments: Every payment you make on Made-in-China.com is protected by the platform.
Refund policy: Claim a refund if your order doesn't ship, is missing, or arrives with product issues.
Manufacturer/Factory & Trading Company

360° Virtual Tour

Secured Trading Service
Diamond Member Since 2014

Suppliers with verified business licenses

Audited Supplier

Audited by an independent third-party inspection agency

Number of Employees
48
Year of Establishment
2022-08-15
  • Rapid Response Residential Fire Sprinkler System Concealed Fire Sprinkler Heads
  • Rapid Response Residential Fire Sprinkler System Concealed Fire Sprinkler Heads
  • Rapid Response Residential Fire Sprinkler System Concealed Fire Sprinkler Heads
  • Rapid Response Residential Fire Sprinkler System Concealed Fire Sprinkler Heads
  • Rapid Response Residential Fire Sprinkler System Concealed Fire Sprinkler Heads
  • Rapid Response Residential Fire Sprinkler System Concealed Fire Sprinkler Heads
Find Similar Products
  • Overview
  • Product Description
  • Our Advantages
  • FAQ
  • Packaging & Shipping
Overview

Basic Info.

Model NO.
SA-0003
Alarm Valve Type
Wet Alarm Valve
Automatically Opened and Closed Repeatedly
Can′t Automatically Opened and Closed
Open Fire Sprinkler System Type
Water Spray System
Closed Fire Sprinkler System
Wet Fire Sprinkler System
Dry Alarm Valve Type
Enclosed Type
Wet Alarm Valve Structure
Seat Type
Alarm Valve Diameter
80mm
Nozzle Flow Coefficient
80
Deluge Valve Type
Diaphragm Type
Item
Fire Sprinkler Heads
Raw Material
Stainless Steel, Carbon Steel, Aluminum, Brass
Tolerance
+/-0.02mm
Techincs
Machining
Brand Name
Shengao,OEM
Standard or Nonstandard
Nonstandard
Factory
Over 15 Years Experience in Producing
Dimension
10-100mm
Certificates
SGS, ISO9001:2008
OEM Service
Yes
Csutom Made
Yes
Logo Printing
Customized
MOQ
10-1000PCS
Free Sample
Yes
Length
285mm
Transport Package
Plywood Box
Specification
SGS
Trademark
Shengao
Origin
Weifang City, Shandong Province, China
HS Code
7325109000
Production Capacity
500ton/Month

Packaging & Delivery

Package Size
30.00cm * 20.00cm * 40.00cm
Package Gross Weight
10.000kg

Product Description

Rapid Response Residential Fire Sprinkler System Concealed Fire Sprinkler Heads

Product Description

Introduction:
Sprinkler is an important part of wet-type auto spraying system. It is usually installed inside the building and structures with light fire danger, medium fire danger and heavy fire danger, such as workshop, warehouse, hotel, shop, recreational place, hospital, cinema, office building and garage.
The sprinkler is composed of sprinkler frame, sealant and glass bulb. It is to be installed in the protective district via ductwork, acting as a fire detector and auto sprayer. In case of fire inside the protective district, the atmosphere temperature rises up and the liquid inside the glass bulb expands after being heated and explodes after reaching the operating temperature of the glass ball. The sealant drops and the sprinkler sprays to the protective district for fire extinguishments subject to the preset shape of spraying.

 
Type Upright / Pendent /Sidewall/Conventional/Concealed
Material Brass/Zinc
Surface finish Natural brass or Chrom Plated or White Color Coated
Thread diameter 1/2" NPT/BSPT (DN15) 3/4" NPT/BSPT (DN20)
Flow characteristic coefficient 80L/min(K=5.6) 115L/min(K=8.0)
Glass bulb diameter 5mm(Standard Response) or 3mm(Quick Response)
Certificates ISO,CCC,UL
Max working pressure 1.2Mpa (175Psi/12 Bar)
Factory Hydrostatic Test 100%, 3.0Mpa

Rapid Response Residential Fire Sprinkler System Concealed Fire Sprinkler Heads

Product Description
The glass bulb sprinkler head is an important component of a sprinkler system,  the mechanism is that the glass bulb is sensitive to heat, when the surroundings temperature reaches a certain point,   the glass bulb will break and activate the sprinkler to spray water for fire extinguishing. 

The concealed sprinkler head is usually installed at places with luxurious decoration and beautiful appearance,such as antechamber, meeting room, shopping mall, hotel, and recreational center, etc. It can be concealed in the ceiling completely. The color of the cover plate can match with ceiling to make the installed hole hue harmonious.

 

Our Advantages
 

Rapid Response Residential Fire Sprinkler System Concealed Fire Sprinkler Heads

Sprinklers can be used to detect fires,and through automatic sprinkler to control and extinguish fires. 
Automatic sprinkler system is the main components,It's widely used in high-rise buildings,hotels,shopping malls,factories,warehouses and other buildings,to meet the various hazards Level of protection requirements.





Rapid Response Residential Fire Sprinkler System Concealed Fire Sprinkler Heads
Installation,Usage and Maintenance:
During installation, should pay attention not to damage the bulb to avoid affect the thermal performance. In the process of wrench and twist, do not use spanner to wrench the supporting arm to deformation and affect thesealing performance (note: the bulb temperature can be chosen according to the needs of users)
Product Feature:
It can not only detect the fire, but also extinguish the fire by spraying water.


Rapid Response Residential Fire Sprinkler System Concealed Fire Sprinkler Heads

1. The installation distance of the spray head is generally 3.6 meters in diameter and 1.8 meters in radius;
2. The maximum protection area of the sprinkler is 12.5 square;
3. The spray head should not be less than 300mm from the wall;
4. When the distance between the spray head and the ceiling is greater than 80m, and there are combustibles in the ceiling, the    upper and lower sprays are required. 

Rapid Response Residential Fire Sprinkler System Concealed Fire Sprinkler Heads

 
FAQ

Q: What's your payment terms?
A: T/T 30% as deposit, and 70% before delivery. We'll show you the photos of the products and packages before you pay the balance.
Q4. What is your term of delivery?
A: EXW, FOB, CFR, CIF, DDU.
Q5. How about your delivery time?
A: Generally, it will take 10 to 20 days after receiving your advance payment. The specific delivery time depends on the items and the quantity of your order.
Q6. Can you produce according to the samples?
A: Yes, we can produce by your samples or technical drawings. We can build the molds and fixtures.
Q7. What is your sample policy?
A: We can supply the sample if we have ready parts in stock, but the customers have to pay the sample cost and the courier cost.
Q8. Do you test all your goods before delivery?
A: Yes, we have 100% test before delivery.
Q9. How do you make our business long-term and good relationship?
A:1. We keep good quality and competitive price to ensure our customers' benefit;
2. We respect every customer as our friend and we sincerely do business and make friends with them, no matter where they come from.

 

 
Packaging & Shipping

Rapid Response Residential Fire Sprinkler System Concealed Fire Sprinkler Heads

     Quality First,Price Best,Service Foremost!
     We assure you of our best services at all times!
     If you are interested in product,please click " SEND " for more details.

Send your message to this supplier

*From:
*To:
*Message:

Enter between 20 to 4,000 characters.

This is not what you are looking for? Post a Sourcing Request Now
Contact Supplier